10. Clock Interface

10.5 Connecting Clocks to a System without Phase Locking


When the R4000 processor is used in a system in which the external agent cannot lock its phase to a common MasterClock, the output clocks RClock and TClock can clock the remainder of the system. Two clocking methodologies are described in this section: connecting to a gate-array device or connecting to discrete CMOS logic devices.